Page 8 AD-4405 Weighing Indicator 4.4.4.4. Description of Panels and symbolsDescription of Panels and symbolsDescription of Panels and symbolsDe
AD-4405 Weighing Indicator Page 9 ZERO key The key to zero the current display. CLEAR key The key to clear the setting value. TARE key The
Page 10 AD-4405 Weighing Indicator 4.1.4. Accessories and options Standard accessoriesStandard accessoriesStandard accessoriesStandard accessories
AD-4405 Weighing Indicator Page 11 5.5.5.5. CalibrationCalibrationCalibrationCalibration This indicator, converts an input voltage from a l
Page 12 AD-4405 Weighing Indicator Note that the ON/OFF key does not function alone. Press the ESC key while holding the ON/OFF key to end the calibr
AD-4405 Weighing Indicator Page 13 Dual Range <First range> Select the resolution, decimal point position and format. ¯ <First range> S
Page 14 AD-4405 Weighing Indicator SpecifyiSpecifyiSpecifyiSpecifying ng ng ng the Weighing Range of the First Rangethe Weighing Range of the First R
AD-4405 Weighing Indicator Page 15 5.2.3. Zero Calibration Procedure Step 8 Check the Cal 0 display. Select a zero calibration method to adjust
Page 16 AD-4405 Weighing Indicator Weighing a Mass less than the Maximum Capacity Step12 Set a mass value using the 0 - 9 keys. Step13 Place a mass
AD-4405 Weighing Indicator Page 17 ESC key ... The key to store the parameters temporarily. Proceed to the Cal 0 display. Press and hold the O
This manual and Marks All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Ins
Page 18 AD-4405 Weighing Indicator 5.3.1. Setting the Division and Range Consider the following rules to design the weighing range. Rule 1 Select
AD-4405 Weighing Indicator Page 19 5.5.5.5.5.5.5.5. Gravity Compensation FunctionGravity Compensation FunctionGravity Compensation FunctionGrav
Page 20 AD-4405 Weighing Indicator 5.5.1. The Gravity Acceleration Table Amsterdam 9.813 m/s2 Manila 9.784 m/s2 Athens 9.800 m/s2 Melbourne 9.80
AD-4405 Weighing Indicator Page 21 5.6.5.6.5.6.5.6. Calibration Error CodCalibration Error CodCalibration Error CodCalibration Error Code Liste
Page 22 AD-4405 Weighing Indicator 6.6.6.6. FunctionsFunctionsFunctionsFunctions There are two parameters lists, one for the F-functions an
AD-4405 Weighing Indicator Page 23 6.2.6.2.6.2.6.2. FFFF----FunctionsFunctionsFunctionsFunctions Weighing Conditions (Digital Filter, Zero tr
Page 24 AD-4405 Weighing Indicator Display and Other General Functions Item Parameter Description * 0 5 times/s f04 Display update rate 1 10 times/
AD-4405 Weighing Indicator Page 25 External Input Item Parameter Description ** 0 Not used (No function) 1 ZERO key 2 TARE key 3 NET/GROSS key 4 O
Page 26 AD-4405 Weighing Indicator Comparator Item Parameter Description * 0 Not used 1 Upper/lower limit comparison (2 Limits setting) 2 Upper/lowe
AD-4405 Weighing Indicator Page 27 Data Output Item Parameter Description ** 0 No data output 1 Analog output Set f31, 32, 33 2 Serial output f3
AD-4405 Weighing Indicator, Instruction Manual, A&D Co., ltd. Contents 1. Compliance...
Page 28 AD-4405 Weighing Indicator Current Loop Output Item Parameter Description ** 0 Displayed data 1 Gross data 2 Net data 3 Tare data f36 Output
AD-4405 Weighing Indicator Page 29 Serial Interface Item Parameter Description ** 0 Stream mode, command is not acceptable 1 Manual mode, command i
Page 30 AD-4405 Weighing Indicator Calendar / Clock Function Item Parameter Description *0 12hrs. display (00 to 11, AM / PM)f50 Time display 1 24hr
AD-4405 Weighing Indicator Page 31 Print Format Item Parameter Description x 0 No print 0 0 : Line feed only x 1 Device number ID# The number de
Page 32 AD-4405 Weighing Indicator 6.3.6.3.6.3.6.3. CFCFCFCF----FunctionsFunctionsFunctionsFunctions Item Parameter Description * 0 No limit
AD-4405 Weighing Indicator Page 33 7.7.7.7. TareTareTareTare The function is used to display a net value with the container weight subtract
Page 34 AD-4405 Weighing Indicator 8.8.8.8. AccumulationAccumulationAccumulationAccumulation This function accumulates weighing data and s
AD-4405 Weighing Indicator Page 35 8.1.2. Display and Operation Action of Accumulating Data When accumulating data, the display blinks once.
Page 36 AD-4405 Weighing Indicator Output of Accumulated Data Accumulated data can be output to the serial interface. Output by manual or aut
AD-4405 Weighing Indicator Page 37 9.9.9.9. Code Memory Code Memory Code Memory Code Memory This indicator has four Code memories (1 th
Page 2 AD-4405 Weighing Indicator 9.1.1. Using Code Memory ...
Page 38 AD-4405 Weighing Indicator Changing the Code Memory Number by External Input The code memory number can be changed by external input from
AD-4405 Weighing Indicator Page 39 There are 3 type of setting values for each comparison. (1) Set the limit value (upper and lower limit / HiHI
Page 40 AD-4405 Weighing Indicator 10.1.2. Setting the Upper/Lower Limit Values Step 1 By pressing the SETPOINT key, the selected code memory numbe
AD-4405 Weighing Indicator Page 41 10.2.10.2.10.2.10.2. Setpoint ComparisonSetpoint ComparisonSetpoint ComparisonSetpoint Comparison This
Page 42 AD-4405 Weighing Indicator F22 = 9 (Check weighing 3:Loss in weight)F22 = 9 (Check weighing 3:Loss in weight)F22 = 9 (Check weighing 3:Loss i
AD-4405 Weighing Indicator Page 43 Toward the Zero bandToward the Zero bandToward the Zero bandToward the Zero band Preliminary and Free fall
Page 44 AD-4405 Weighing Indicator 11.11.11.11. Hold FunctionHold FunctionHold FunctionHold Function This function displays the hold weigh
AD-4405 Weighing Indicator Page 45 f28 determines the averaging time by 0.1second step. f28 0 holds the data at averaging start. The key swi
Page 46 AD-4405 Weighing Indicator 12.12.12.12. Counting FuncCounting FuncCounting FuncCounting Functiontiontiontion This function determi
AD-4405 Weighing Indicator Page 47 ENTER key...The key to register the unit weight and return to the piece count display. The unit weig
AD-4405 Weighing Indicator Page 3 1.1.1.1. ComplianceComplianceComplianceCompliance 1.1.1. Compliance with FCC Rules Please note that this
Page 48 AD-4405 Weighing Indicator 13.13.13.13. Calendar / ClockCalendar / ClockCalendar / ClockCalendar / Clock The AD-4405 has a built-in c
AD-4405 Weighing Indicator Page 49 f53 2 Add 2 digit alphabetical characters including space or dot. There are 3 types, a character and a space,
Page 50 AD-4405 Weighing Indicator Step 3 After displaying the date format for 2 seconds, the present date is displayed in f51 format. The f52 param
AD-4405 Weighing Indicator Page 51 14.14.14.14. Internal Printer (OPInternal Printer (OPInternal Printer (OPInternal Printer (OP----06)06)06)06)
Page 52 AD-4405 Weighing Indicator 14. Internal Printer (OP-06) Installing the Printer Paper (Special roll paper) Step 1 Open the cover. Step 2
AD-4405 Weighing Indicator Page 53 15.15.15.15. Common Printer and Data OutputCommon Printer and Data OutputCommon Printer and Data OutputCommo
Page 54 AD-4405 Weighing Indicator Description of "Command Mode" (For Serial Interface) Function f40 5 Operation The serial data can be o
AD-4405 Weighing Indicator Page 55 15.3.1. Setting the Interval Time Step 1 By pressing the SETPOINT(3) key while pressing the PRINT key, intv
Page 56 AD-4405 Weighing Indicator 16.16.16.16. RSRSRSRS----232C Interface232C Interface232C Interface232C Interface 16.1.16.1.16.1.16.1. S
AD-4405 Weighing Indicator Page 57 16.2.16.2.16.2.16.2. Data FormatData FormatData FormatData Format There are two data format types set
Page 4 AD-4405 Weighing Indicator 2.2.2.2. IntroIntroIntroIntroductionductionductionduction The AD-4405 is a weighing indicator that amplif
Page 58 AD-4405 Weighing Indicator 16.3.16.3.16.3.16.3. Command FormatCommand FormatCommand FormatCommand Format Explanation of CommandExplanat
AD-4405 Weighing Indicator Page 59 16.3.1. Commands to Request Data Request Request Request Request for the for the for the for the Display Data (1
Page 60 AD-4405 Weighing Indicator 16.3.2. Commands to Control the Indicator Zero Zero Zero Zero the the the the DisplayDisplayDisplayDisplay
AD-4405 Weighing Indicator Page 61 Changing the Weight UnitChanging the Weight UnitChanging the Weight UnitChanging the Weight Unit Changes t
Page 62 AD-4405 Weighing Indicator 16.3.3. Commands to Set Parameters Set Set Set Set the the the the Limit/Setpoint ValueLimit/Setpoint ValueLimit/
AD-4405 Weighing Indicator Page 63 16.3.4. Commands for the Hold Function Start Averaging to HoldStart Averaging to HoldStart Averaging to HoldStar
Page 64 AD-4405 Weighing Indicator 16.4.16.4.16.4.16.4. UFC CommandUFC CommandUFC CommandUFC Commandssss UFC (Universal Flexi Coms) functi
AD-4405 Weighing Indicator Page 65 $DL Inserting a DeLay time (0.1 second step) Example: DL10 : 1.0 second delay Strings Output or print spec
Page 66 AD-4405 Weighing Indicator 17.17.17.17. RSRSRSRS----422/RS422/RS422/RS422/RS----485, Relay Output(OP485, Relay Output(OP485, Relay Output
AD-4405 Weighing Indicator Page 67 Switching Between RSSwitching Between RSSwitching Between RSSwitching Between RS----422/RS422/RS422/RS422/RS----4
AD-4405 Weighing Indicator Page 5 3.3.3.3. Installation and PrecautionsInstallation and PrecautionsInstallation and PrecautionsInstallation and
Page 68 AD-4405 Weighing Indicator 18.18.18.18. Relay Output & Control Input (ORelay Output & Control Input (ORelay Output & Control
AD-4405 Weighing Indicator Page 69 19.19.19.19. 4444----20mA Analog Output (OP20mA Analog Output (OP20mA Analog Output (OP20mA Analog Output (OP
Page 70 AD-4405 Weighing Indicator 20.20.20.20. Current Loop Output (OPCurrent Loop Output (OPCurrent Loop Output (OPCurrent Loop Output (OP----0
AD-4405 Weighing Indicator Page 71 Current LoCurrent LoCurrent LoCurrent Loop Outputop Outputop Outputop Output The current loop output can be
Page 72 AD-4405 Weighing Indicator 21.21.21.21. SpecificationsSpecificationsSpecificationsSpecifications Analog Input and A/D ConversionAnalog
AD-4405 Weighing Indicator Page 73 GeneralGeneralGeneralGeneral Power supply Selection by internal connector from 100V AC, 120V AC, 200V AC and
Page 74 AD-4405 Weighing Indicator MEMO
AD-4405 Weighing Indicator Page 75 MEMO
Page 76 AD-4405 Weighing Indicator MEMO
Page 6 AD-4405 Weighing Indicator 3.1.3. Adjustment of the Load Cell Output Caution Use a metal film resistor in the range of 50kohm to 500kohm
AD-4405 Weighing Indicator Page 7 3.1.5. Installing an Option Board This is the procedure for the data output board (OP-03, OP-05, OP-07 and OP-0